Nominal power (or peak power) is the nameplate capacity of photovoltaic (PV) devices, such as solar cells, modules and systems. It is determined by measuring the electric current and voltage in a circuit, while varying the resistance under precisely defined conditions. The nominal power is important for designing an installation in order to correctly dimension its cabling and converters.
Nominal power is also called peak power because the test conditions at which it is determined are similar to the maximum irradiation from the sun. Thus this quantity approximates the theoretical maximum production of the panel on a clear sunny day with the panel oriented perpendicular to the sun. The nominal power is generally not reached under actual radiation conditions. In practice, actual conditions will allow for approximately 15-20% lower generation due to the considerable heating of the solar cells.
Moreover, in installations where electricity is converted to AC, such as solar power plants, the actual total electricity generation capacity is limited by the inverter, which is usually sized at a lower peak capacity than the solar system for economic reasons. Since the peak DC power is reached only for a few hours each year, using a smaller inverter allows to save money on the inverter while clipping (wasting) only a very small portion of the total energy production. The capacity of the power plant after DC-AC conversion is usually reported in WAC as opposed to WDC or Watt-peak (Wp).
Standard test conditions
This section needs additional citations for verification. Please help improve this article by adding citations to reliable sources in this section. Unsourced material may be challenged and removed. (September 2021) (Learn how and when to remove this message) |
The nominal power of PV devices is measured under standard test conditions (STC), specified in standards such as IEC 61215, IEC 61646 and UL 1703. Specifically, the light intensity is 1000 W/m, with a spectrum similar to sunlight hitting the Earth's surface at latitude 35°N in the summer (airmass 1.5), the temperature of the cells being 25 °C. The power is measured while varying the resistive load on the module between an open and closed circuit (between maximum and minimum resistance). The highest power thus measured is the 'nominal' power of the module in watts. This nominal power divided by the light power that falls on a given area of a photovoltaic device (area × 1000 W/m) defines its efficiency, the ratio of the device's electrical output to the incident energy.
Units
This section needs additional citations for verification. Please help improve this article by adding citations to reliable sources in this section. Unsourced material may be challenged and removed. (September 2021) (Learn how and when to remove this message) |
In the context of domestic PV installations, the kilowatt (symbol kW) is the most common unit for nominal power, for example Ppeak = 1 kW. Colloquial English sometimes conflates the quantity power and its unit by using the non-standard label watt-peak (symbol Wp), possibly prefixed as in kilowatt-peak (kWp), megawatt-peak (MWp), etc. For example, a photovoltaic installation may be described as having "one kilowatt-peak of power" ("P = 1 kWp"). However, in the International System of Units (SI), the physical unit (and its symbol) should not be used to provide specific information about the conditions assumed for measuring a given physical quantity.
Conversion from DC to AC
Solar power needs to be converted from direct current (DC, as it is generated from the panel) to alternate current (AC) to be injected into the power grid. Since solar panels generate peak power only for few hours each day, and DC to AC converters are expensive, the converters are usually sized to be smaller than the peak DC power of the panels. This means that for some hours each day the peaks are "clipped" and the extra energy is lost. This has very little impact on the total energy generated throughout a year, but saves considerable amount of balance of system (BOS) costs. Due to under-sizing of converters, AC ratings of solar plants are generally significantly lower than DC ratings, as much as 30%. This in turn increases the calculated yearly capacity factor of the plant. The downrating of peak power and the related clipping is different from the losses incurred in the conversion from DC to AC, which happen at any power level and are usually relatively small.
Most countries refer to installed nominal nameplate capacity of PV systems and panels by counting DC power in watt-peak, denoted as Wp, or sometimes WDC, as do most manufacturers and organizations of the photovoltaic industry, such as Solar Energy Industries Association (SEIA), the European Photovoltaic Industry Association (EPIA) or the International Energy Agency (IEA-PVPS). Some grid regulations may limit the AC output of a PV system to as little as 70% of its nominal DC peak power (Germany). Because of these two different metrics, international organizations need to reconvert official domestic figures from the above-mentioned countries back to the raw DC output in order to report coherent global PV-deployment in watt-peak.
In order to clarify whether the nominal power output (watt-peak, Wp) is in fact DC or already converted into AC, it is sometimes explicitly denoted as MWDC and MWAC or kWDC and kWAC. The converted WAC is also often written as "MW (AC)", "MWac" or "MWAC". Just as for Wp, these units are non SI-compliant but widely used. In California, for example, where the rated capacity is given in MWAC, a downrating of 15 percent in the conversion from DC to AC is assumed.
Power output in real conditions
This section needs additional citations for verification. Please help improve this article by adding citations to reliable sources in this section. Unsourced material may be challenged and removed. (September 2021) (Learn how and when to remove this message) |
The output of photovoltaic systems varies with the intensity of sunshine and other conditions. The more sun, the more power the PV module will generate. Losses, compared to performance in optimal conditions, will occur due to non-ideal alignment of the module in tilt and/or azimuth, higher temperature, module power mismatch (since panels in a system are connected in series the lowest performing module defines performance of the string it belongs to), aging factor, soiling and DC to AC conversion. The power a module generates in real conditions can exceed the nominal power when the intensity of sunlight exceeds 1000 W/m (which corresponds roughly to midday in summer in, for example, Germany), or when sun irradiation close to 1000 W/m happens at lower temperatures.
References
- Die Verwirrung um das Watt-Peak, The confusion around watt-peak, 14 August 2009.
- ^ "What does kilowatt peak (kWp) actually mean?". solar-is-future.com. 2011. Archived from the original on 12 June 2015. Retrieved 11 June 2015.
- International Bureau of Weights and Measures (2006), The International System of Units (SI) (PDF) (8th ed.), p. 132, ISBN 92-822-2213-6, archived (PDF) from the original on 2021-06-04, retrieved 2021-12-16
- "Global Market Outlook for Photovoltaics 2014-2018" (PDF). epia.org. EPIA - European Photovoltaic Industry Association. p. 15. Archived from the original (PDF) on 25 June 2014. Retrieved 12 June 2014.
- "Snapshot of Global PV 1992-2014" (PDF). iea-pvps.org/index.php?id=32. International Energy Agency — Photovoltaic Power Systems Programme. 30 March 2015. p. 11. Archived from the original on 7 April 2015.
- Gipe, Paul (20 November 2009). "Solar PV DC Conversion Factor for AC kW". Wind Works. Archived from the original on 15 September 2013. Retrieved 23 January 2020.
Photovoltaics | |||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|
Concepts | |||||||||||
Photovoltaic system | |||||||||||
Applications |
| ||||||||||
Generation systems |
| ||||||||||
PV companies |
| ||||||||||